Nuclear swamp stinger power station reactor component. 250,000 MW (part 1 of 2)
---Update note Recent update on 10-2 to move the nitric acid production to the new node location after a recent update move the nitrogen well located west of blue crater by about 100m
The first few survey missions Ficsit sent to Massage-2 (A-B)b noticed a strange power anomaly in the swamp. The first pioneer drop pod sent to the swamp lost it's video feed just after landing; the last image showed a massive uranium infused stinger capable of self nuclear reactions. Ficsit immediately dropped several more Pioneer teams to the swamp with the goal of capturing and harnessing this meta-stinger to power the upcoming space elevator project. Though all 96 pioneers died during there efforts, they managed to build an unrivaled power plant for the next pioneer's arrival.
This massive build project with a 100 reactor power plant is actually 1 piece of the entire nuclear power site. It has the reactors, entire water feed setup, sulfuric and nitric acid production, concrete production, drone relays for bringing in uranium, fuel rod manufacturers, and every part of chain for making uranium cells and recycling nuclear waste. There is actually a companion megaprint titled "Nuclear Swamp Stinger Production Facilities" https://satisfactory-calculator.com/en/megaprints/index/details/id/1467/name/Nuclear+Swamp+Stinger+Production+Facilities that mostly merges with this reactor build. This companion megaprint handles building the non-radioactive components needed for fuel and recycling production, only needing a manual connection of 3 mk5 belts and 2 power cables to activate. It also contains a swamp spanning rail and vehicle bridge.
This power plant segment was designed to run stand alone for those that do not want to add the production factory segment, but needs the following:
15,0000 MW either from a power grid or from stored battery power to kick start all production or pumps before the reactors kick in. -Encased beams = 65 PPM -pressure cubes = 10PPM -electromagnetic control rods = 105 PPM -Silica = 670 PPM -aluminum casing = 180 PPM -batteries = 60 PPM All other resources already produce themselves. The belt connection points have images on signs showing what items need to connect to which belts. Also allow about 5 minutes from supplying outside power to connect needed parts to allow fluid and concrete buildup to start
This is a lot more of an exercise in balancing a massive production chain than beautiful builds, though it definitely has a creative layout and design I did have considerably more intricacy and build design (twisted pipes, more spread out production per pod, hypertube network from the control room to each pod), but the issue was that the blueprint was weighing in at 5.8 MB and had to undergo significant trimming to meet the upload limit. Original construction on the reactor site was done in update 5 before swamp layout changes. Most minor intrusions from the update 6 changes have been worked around, but there is a "perma-spore-tree" that is going through the central platform that couldn't be avoided or worked around. Be gentle in the ratings, there are a lot of "floating platforms and exposed belts in the structure along with some overclocked factory machines to reduce blueprint items; I had limited wiggle room to play with to meet the upload limit.
I can be reached at Yokmosho on Discord with any issues encountered, comments, ect.
- Nombre d'objets 59 009
- Coordonnées 118 516 / -3 967
- Coller uniquement à l'emplacement d'origine Yes
- Catégories Architecture Complete factory Interior decorations Exterior decorations Pipes system UPDATE 7 UPDATE 8
-
Évaluation
3 / 5
- Version 249 836
- Auteur Yokmosho
- Télécharger (736x) Télécharger
- Taille du fichier 3,97 MB
- Created on 28 août 2023 01:16:14
- Dernière mise à jour le 3 oct. 2023 02:46:01
- Mur 4m 9 171
- Fondation 1m 5 698
- Cadre de fenêtre hexagonal 4 656
- Petit pilier en métal 3 990
- Toit 1m 3 165
- Mur en charpente métallique 2 820
- Mur 4m 2 560
- Fondation 1m 2 031
- Pipeline Mk.2 1 894
- Convoyeur Mk.5 1 621
- Double rampe 4m 1 386
- Fondation en charpente métallique 1 335
- Ligne électrique 1 290
- Toit plat 1 195
- Support de pipeline empilable 972
- Mur 4m 971
- Fondation 1m 893
- Toit 1m 800
- Convoyeur vertical Mk.1 676
- Passage de sol pour convoyeurs verticaux 606
- Pipeline Mk.1 601
- Convoyeur vertical Mk.5 588
- Toit plat 495
- Croisement de pipeline 426
- Pylône de convoyeur 405
- Coin haut inversé 1m 400
- Convoyeur Mk.1 383
- Double rampe 8m 370
- Double rampe 4m 370
- Répartiteur de convoyeurs 318
- Rampe inversée 2m 316
- Passage de sol pour pipelines 283
- Groupeur de convoyeurs 273
- Poutre peinte 260
- Connectique pour poutre 240
- Prise murale Mk.1 226
- Pompe à eau 219
- Fondation 2m 206
- Support pour pipeline 192
- Panneau vertical 180
- Petit panneau d'affichage 176
- Toit plat 170
- Poteau électrique Mk.1 155
- Rampe en charpente métallique 148
- Pylône de convoyeur empilable 135
- Rampe murale 8m 118
- Répartiteur intelligent 117
- Mur incliné 8m 115
- Cadre de rampe inversé 110
- Mur incliné 8m 110
- Rampe murale inversée 8m 107
- Pompe de Pipeline Mk.2 106
- Tour d'éclairage 100
- Centrale nucléaire 100
- Mélangeur 81
- Façonneuse 50
- Support mural pour pipeline 47
- Rampe 2m 46
- Toit plat 45
- Convoyeur Mk.2 41
- Poutre métallique 40
- Raffinerie 40
- Poteau électrique Mk.3 38
- Constructeur 35
- Support de plafond pour convoyeur 33
- Rampe 2m 29
- Support mural pour convoyeur 29
- Toit 4m 25
- Coin haut inversé 1m 21
- Double rampe 8m 20
- Fondation 4m 20
- Mur incliné 4m 20
- Cadre de fenêtre entier 19
- Accélérateur de particules 18
- Mur avec passage de 1 convoyeur 17
- Héliport 16
- Packageur 14
- Poteau électrique Mk.2 14
- Assembleuse 12
- Double prise murale Mk.1 12
- Rampe 1a 11
- Panneau de contrôle des lumières 11
- Double rampe 8m 10
- Rampe 4m 10
- Rampe 4m 10
- Rampe inversée 2m 10
- Fondation 2m 10
- Rampe inversée 1m 10
- Coin haut inversé 1m 10
- Fondation 1m 10
- Mur incliné 4m 10
- Mur avec passage de 3 convoyeurs 10
- Mur 1m 10
- Pipeline Mk.1 (sans indicateur) 10
- Toit 2m 9
- Foreuse Mk.3 9
- Demi-fondation 1m 8
- Petit pilier en béton 8
- Extracteur de puits de ressources 7
- Panneau carré 0.5m 6
- Porte automatique 4
- Rampe murale 1m 4
- Conteneur de stockage 4
- Répartiteur programmable 4
- Panneau d'étiquetage 2m 3
- Broyeur A.W.E.S.O.M.E. 3
- Pipeline Mk.2 (sans indicateur) 3
- Double rampe 2m 2
- Petit support de pilier 2
- Rampe murale 2m 2
- Mur avec passage de 2 convoyeurs 2
- Échelle 2
- Rampe inversée 4m 1
- Demi-fondation 1m 1
- Toit 1m 1
- Plafonnier 1
- Rampe murale 4m 1
- Panneau d'étiquetage 4m 1
- Foreuse Mk.2 1
- Pressuriseur 1
- Générateur géothermique 1
- Onduleur 1
- Conteneur industriel 1
- Convoyeur vertical Mk.4 1
- Béton 142 523
- Poutre en acier 23 931
- Câble 15 026
- Plaque de fer 13 883
- Tôle d'aluminium en alliage Alclad 13 597
- Tôle de cuivre 12 859
- Silice 9 350
- Tige de fer 5 676
- Plastique 5 455
- Boîtier en aluminium 4 850
- Cadre modulaire lourd 4 150
- Plaque de fer renforcée 3 451
- Filactif 2 786
- Moteur 2 536
- Rotor 2 472
- Poutre en béton armé 2 214
- Cristal de quartz 1 816
- Tige de contrôle électromagnétique 1 800
- Tuyau en acier 1 793
- Fil électrique 1 781
- Unité de contrôle radio 1 015
- Système de refroidissement 900
- Supercalculateur 737
- Cadre modulaire fusionné 450
- Connecteur haute vitesse 439
- Caoutchouc 384
- Moteur turbo 207
- Oscillateur à cristal 176
- Contrôleur d'I.A. 150
- Foreuse portable 29
- Cadre modulaire 20
- Stator 5
-
Yokmosho - 2 janv. 2024 15:55:52
I worked quite a bit with GrOOvER regarding the backing up of waste and overall cascade failure. My testing did not reproduce the same result, but the server GrOOvER had the powerplant running on had a Smart splitter and a Programmable splitter located in a pretty critical area spontaneously fail to function. Deleting them and replacing them fixed the issue. This was in the production half of the megaprint, not the powerplant half. I'll have an updated print uploaded with these splitters deleted and readded
-
gOOvER - 27 déc. 2023 07:03:53
I like the design and spent 12 hours yesterday trying to bring order to the quaos. Unfortunately this is not possible. Everything is also full of nuclear waste and all the belts are blocked.
Super design, but implementation is misserable. Therefore only 2 stars
-
Yokmosho - 14 sept. 2023 17:05:29
DoeBIG:
I am fully aware of the belt and pipe spaghetti mess mainly limited to the main area of the “wet factory” and leading into the transfer room for the integration between the 2 halves of the print. The original build was much cleaner and more streamlined, but I ran into several issues:
- The entire factory was build on production lines filling and going to the next phase as it was built. Running it from a completely empty state was a disaster and had to have a lot of reformatting with overflows and backflows to stabilize. I attempted to do some tidying up after everything was working, but that hit the biggest and next issue polish
- Upload size: I’m not exaggerating in saying that had to do a massive amount of cuts to fit the megaprint upload limits. I had to remove walls, have less power connectors and string cables all over the place, ect. to trim every object I could to lower size. Several of those “spaghetti knots” of cables would have required extra walls, ceiling and wall belt supports, and lots of short belt segments to straighten out; I just didn’t have the file size overhead to play with and had to leave an uncomfortable number of long floating belts.. If a nice clean setup is all your looking for, I have a project in the works that is a main storage and delivery base, along with an ammo factory. It has a much smaller file size and is leaving a lot more room for.
-
DoeBIG - 8 sept. 2023 22:02:22
Interested building, amazing bridge and then you found awful interior. Spaghetti belts and pipes. Same with cables...what is wrong with you mate, why you did not build at least pipes and belts correctly? Wanted to try power plants, but after integrating and looking inside amazing building, i was disgusted and deleted it So i cant confirm functionality.
-
Yokmosho - 4 sept. 2023 04:51:04
I found the issue regarding a few smart spitters not behaving correctly and causing a slow water buildup on the recycling line. I've tested past 8 hours with no issues found so far. Please redownload the updated megaprint to correct the fault.
-
Andreas61 - 2 sept. 2023 12:45:53
Does not work. It starts as described, then after 6-7 hours of operation it stops and that's it.